May 2014
When inspecting a BX, R, or RX seal ring groove with a Gagemaker BX-1000, the groove width can be obtained by inspecting the minor and major diameters. To measure the minor diameter, simply reverse the spring’s direction on the gage and re-set.* First, measure the major diameter. Second, invert the spring. Then after setting, measure […]