When inspecting thread run-out on buttress connections 16″ and over (1″ TPF), API 5B requires setting the gage to zero on the perfect threads of the part as opposed to zeroing on a flat surface.
As 1″ TPF buttress threads are stairstepped, their thread roots are parallel to the thread axis, while ¾” TPF Buttress roots are parallel to the taper cone.