Gage Tip of the Month

December 2016

While a certified Gagemaker setting standard is the preferred practice for Straight Threads, in a pinch,  you can use gage blocks to set a two-point Gagemaker lead gage without a proper standard. Create a gage block stack-up for the necessary interval then place between the points. Hold the face of the stackup against the fixed […]

Gage Tip of the Month

February 2015

For zeroing pitch diameter gages on an internal rod standard, Gagemaker recommends using our new RSV fixtures to align the contact points enabling easier, consistent, repeatable zeros. Normally to zero the gage, you must sweep the point on the standard in two directions to obtain the lowest possible indication. To consistently find the ideal setting […]